Controlador Vhm-014 Control Humedad / Temperatura / Luz Itytarg

MLA770523182

Nuevo producto

4 artículos

compartir

$ 40.250,00 IVA Inc.

Más

Controlador de usos múltiples (no simultáneos)

Control de humedad de suelo / temperatura / luz, según selección de un jumper

XH-M214 Humidity Controller Soil Sensor Module 20-99%RH Precise Automatic Control Irrigation System Red Digital Display

VHM-014 Humidity Controller Soil Sensor Module 20-99%RH Automatic Control Irrigation Computer System Red Digital Display Module
Product model: VHM-014
Power supply: DC 12V
Output mode: output switch
Humidity range: 20~99%
Photometric accuracy: 1% RH
Temperature range: 0-60°
Temperature accuracy: ±2°
Control current: 5A
Product net weight: about 28g
Product size: 45*43*18mm

1. Description:

The probe can be inserted directly into the soil. It is a digital display of soil moisture. When the humidity is below the set value starting pump starts watering, when humidity reaches the set value to stop watering. The operation is very simple. It is intelligent humanization.

 

2. Parameters:

No.

Parameter

Value

1

Product name

Soil Moisture Controller Module

2

Model

XH - M214

3

Power supply voltage

DC 12 V

4

Output way

Output switch

5

Humidity range

20-99% RH

6

Control precision

1% RH

7

Control current

10 A

8

Net weight

About 28 g

9

Size

52 * 43 * 16 mm

 

3. Using attention:

Please follow the wiring diagram of the description. You can choose the appropriate wiring mode according to the load voltage you use

1>. F0 setting start humidity(the humidity of the solenoid valve or the pump start working)

Press the “SET” button to display “F0” and press the “SET” button to display the start humidity, and press +/ button to “SET” the humidity value

2>. F1 setting stop humidity (the humidity of the solenoid valve or the pump stops working)

Press +/- button to switch to “F1”, press the “SET”  button to display the stop humidity value, and press +/ button to SET the humidity value

3>. F2 humidity correction

Normal use without correction error.The correction of values in the use of multiple modules at the same time is conducive to a unified management operation.